
A 120 × 320 cm (1200 × 3200 mm) slab is tall enough to clad a double-height wall in one piece and wide enough to cut joints down to a minimum. Architects specify it when they want a surface to read as a single material, not a collection of tiles. This guide covers what to decide before you order.
What is available
At Lumina Tile, this size is part of the Large Slab Tiles category, in 6, 9, 12, 15 and 20 mm thickness. Surfaces are Glossy, Matt and Carving. Neighbouring sizes in the slab range include 120 × 240 cm and 120 × 280 cm, which share the same width, so you can mix heights where ceilings differ without changing the visual width of the joint pattern.
Why 3.2 metres
Most commercial ceilings fall between 2.7 and 3.2 metres. A 3.2 m slab covers floor to ceiling in a single piece in a tall lobby, a hotel corridor or a retail unit, and in a standard-height room it can be cut down with a clean, factory-quality edge at one end. Where a ceiling is higher, a second course can be added above, with a joint placed at a planned height, such as the top of a door frame.
Choosing thickness for cladding
| Thickness | Suitability for wall cladding |
|---|---|
| 6 mm | Light, easy to lift, needs full adhesive coverage and a very flat wall |
| 9 mm | Good balance of weight and robustness for interior walls |
| 12 mm | Sturdier, better for areas exposed to knocks, such as corridors |
| 15 and 20 mm | Rarely needed on walls, used where mechanical fixing or heavy impact is expected |
For interior walls, 6 to 9 mm is common. Thinner slabs weigh less per square metre, which reduces the load on the wall and the demands on the fixing. If a wall is in a public corridor where trolleys pass, go thicker.
Fixing, joints and finish
Fixing methods
- Adhesive only. Suitable for interior walls up to moderate heights, on a flat, sound substrate, with full-bed coverage.
- Adhesive plus mechanical support. A hidden ledger or clip at the base carries the weight while adhesive cures. Common for tall interior slabs.
- Ventilated facade system. For exterior cladding, using a rail and clip system designed by an engineer. This is a specialist solution, and the slab thickness and fixing points must be calculated for the building.
Do not improvise on tall slabs. Ask your installer or facade engineer for a fixing statement before ordering.
Joints and details
With rectified edges, you can have joints of 1.5 to 3 mm, or use a mitred edge at external corners to avoid visible edge profiles. A mitre needs an experienced fabricator. Alternatives are trims in metal or stone, or a visible butt joint with a slender grout line. Plan these details at design stage.
Expansion joints at ceiling and floor are still needed. Leave a small gap and close it with a flexible sealant or a shadow-gap profile.
Surface selection
Glossy slabs show every ripple on the wall behind them, so surface prep must be exceptional. Matt hides small imperfections and gives a calmer look in a lobby. Carving adds relief for feature walls, where grazing light brings out the texture. For wet areas, such as shower walls, a polished slab is easy to clean and requires very few joints to seal.
Logistics checklist
- Confirm delivery vehicle access to the building.
- Measure the lift, doors and stair turns against the 3.2 m length. If there is no route, plan for a crane or window lift.
- Check how slabs are crated for export in the packaging details.
- Order spares from the same batch to handle breakage and later repairs.
Pairing with floors and ceilings
A tall slab wall looks best when the floor and ceiling details are planned with it. A shadow gap at the ceiling and a slim skirting or recessed detail at the floor keep the slab edge clean. If the floor is also porcelain, matching the floor tone to the wall gives a continuous feel, while a contrasting floor frames the wall as a feature. In lift lobbies and corridors, check how the slab meets door frames, because the opening dimensions decide where the vertical joints fall.
Common questions
Can I order slabs cut to height?
Slabs are supplied in their standard sizes, and are cut on site or by a fabricator. Discuss your drawings first via the export process.
How do I keep veining consistent across several slabs?
Ask for slabs from the same production run, and lay them out on the floor before fixing to check the sequence.
Where can I see designs?
Browse the large slab range for every design and size.
For a cladding project, share your wall heights and fixing system with Lumina Tile through the contact page and we will help you choose between 120 × 240, 280 and 320 cm.